How to Apply Wind Loads in STAAD.Pro for Solar Structures: Pressure, Uplift and Directions
How to Apply Wind Loads in STAAD.Pro for Solar Structures
Calculating wind pressure and applying it correctly in the model are two different jobs. The first is covered in our article on solar structure wind load calculation as per IS 875 Part 3. This one covers the second: turning a pressure in kN/m² into loads on the right members, in the right directions, for the right cases. For the whole workflow see our pillar guide on solar structure design using STAAD.Pro.
Manual wind loads versus software-generated wind loads
STAAD.Pro has a wind load generator for IS 875 (Part 3):2015. According to Bentley's help, it produces wind intensity versus height values for the code, and the structure types it offers are rectangular clad buildings and unclad frame buildings. It generates loads for the global X and Z directions, works only in Y-up models, and has other documented limitations.
A solar table is neither a clad building nor an ordinary unclad frame. Its net pressures depend on the tilt, the clearance, the position within the array and the table geometry. The generator therefore does not calculate solar-array aerodynamic coefficients for you. The usual approach, which Bentley's own solar articles also describe, is to calculate the wind loads outside the software from the code and project data, then apply them as user-defined loads. Using the generator on a solar table without understanding what it assumes can give loads that look precise and are wrong.
Step 1: Create the model and identify exposed areas
Build the model first, including purlins, so that loads can be applied to real members. Then identify the area that receives wind:
• The module surface, which transfers pressure to purlins
• Exposed structural members (rafters, columns, bracing), whose own wind exposure is usually small compared with the modules, but may be included if the design basis requires it
• Edge or end tables, which may carry higher local pressures than interior tables
Step 2: Determine pressure and suction outside the software
Prepare a calculation sheet that shows the design wind speed, design pressure, net pressure coefficients and the resulting pressures for each case. Keep at least two pressures separate for each direction: the downward (pressure) case and the uplift (suction) case, and where the code gives different values for different zones of the table, keep them as separate zones. Keep the calculation traceable so a reviewer can follow it.
Step 3: Convert pressure into equivalent loads
Converting pressure into loads
For purlins, multiply the area pressure by the tributary width of each purlin:
line load (kN/m) = net pressure (kN/m²) × tributary width (m)
The load acts normal to the module plane. With the assumed values from our earlier articles (pressure 1.045 kN/m² uplift or 0.836 kN/m² downward, tributary width 1.1 m) the line loads are 1.15 kN/m and 0.92 kN/m respectively. Where the code gives different pressures for the front and rear halves of the table, the purlins in each half carry different loads, which creates eccentric loading on rafters and columns.
Choosing member loads or joint loads
• Member loads on purlins are the most direct. Specify a uniformly distributed load in the member's local axis perpendicular to the module plane.
• Joint (nodal) loads at purlin-rafter nodes are useful when purlins are not modelled, with each node taking the load of its tributary area.
• Area or floor loads can apply pressure to a defined panel of members, where the program version and model setup support it.
Bentley notes that loads inclined to the global axes can be applied directly, including inclined nodal loads and linearly varying loads, so engineers need not resolve every force into global components first.
Step 4: Apply loads in the correct directions
Local axes decide the direction of member loads. For a sloping purlin or rafter, a "local Y" load acts perpendicular to the member in its local plane, which may be normal to the module plane or not depending on how the section is oriented. Before running anything:
1. Check the member orientation (beta angle) so that the local axes are what you assume.
2. Apply a small test load and plot the load arrows.
3. Confirm that downward wind and uplift wind arrows point the way you intend.
If the load is given in global axes instead, resolve it as vertical and horizontal components using cos θ and sin θ for the tilt θ.
A short example of member loads, to be adapted to your model's orientation, is shown below. Signs depend on the local axis direction, so always verify by plotting.
LOAD 2 WIND DOWNWARD (PRESSURE) MEMBER LOAD 11 TO 14 UNI Y -0.92 LOAD 3 WIND UPLIFT (SUCTION) MEMBER LOAD 11 TO 14 UNI Y 1.15 |
Confirm the command forms against the technical reference for your STAAD.Pro version.
Step 5: Create the wind directions
A solar table is exposed to wind from several directions, and the governing direction differs by member. A typical set includes:
• Wind from the front (low side) and from the rear (high side), producing the main uplift and downward cases
• Wind along the length of the table (parallel to the rows), which loads end frames and longitudinal bracing
• Oblique wind at about 45°, which produces combined and torsional effects and sometimes governs corners
• Wind reversing where the code gives opposite signs for opposite directions
The code figures for open roofs should be consulted for each direction. Define each as its own primary load case with a descriptive title, for example "WL FRONT UPLIFT" and "WL REAR DOWN".
Step 6: Apply uplift and lateral load cases
Combine the pressure (or suction) with the horizontal component. For a tilted table, wind normal to the surface naturally contains both vertical and horizontal parts. If you apply loads normal to the surface, the program resolves them. If you apply them in global directions, make sure the horizontal component is included, since forgetting it understates bracing and base shear.
Step 7: Create load combinations
Combine dead and wind cases with the factors required by the governing code. Include both the downward and the uplift combinations for each direction, using the reduced dead load factor where dead load helps resist uplift. For guidance, see load cases and load combinations for solar mounting structures. Bentley's documentation describes combination definition as case numbers and factors, and notes that combining results this way applies to linear analysis.
Step 8: Run the analysis and review
Checking reactions
For each wind case, the sum of vertical reactions should equal the vertical component of the applied wind load, and the sum of horizontal reactions the horizontal component. If not, check directions, supports and load application.
Checking member forces
Examine purlin moments against a hand calculation. Check that the rafters and columns show tension where uplift governs and compression where downward wind governs. Look for sign changes in bracing between directions.
Reviewing critical load cases
Use the program's output (or your own spreadsheet) to find the governing combination for each member group and each foundation. Summarise the critical cases, with their reactions, for the report.
Common mistakes
• Using the building wind generator on a solar table and treating its output as final
• Wrong sign or direction, especially for inclined members with rotated local axes
• Applying pressure to the wrong area, or double-counting tributary widths
• Leaving out wind along the table length
• Omitting the horizontal component of normal pressure
• Creating combinations without an uplift case
Frequently asked questions
How do you apply wind load on a solar structure in STAAD.Pro?
Calculate pressure and suction outside the program, convert them to line loads on purlins (or nodal loads), apply them in the correct local or global directions in separate wind cases, and combine them with dead load.
Does STAAD.Pro automatically calculate wind load for solar panels?
No. Its IS 875 (Part 3):2015 generator is intended for rectangular clad buildings and unclad frame buildings, and solar-array coefficients are not generated automatically.
How do I convert wind pressure to a purlin load?
Multiply the net pressure in kN/m² by the purlin's tributary width in metres to get kN/m, applied normal to the module plane.
How many wind directions should I analyse?
At least front, rear, along-table and oblique directions, and more where the geometry or code requires.
How do I know the loads are applied correctly?
Plot the loads, check reactions against the hand-calculated total, and examine force diagrams for plausibility.
What is the difference between manual and generated wind loads?
Manual loads come from your own calculation and are applied as defined. Generated loads come from the program's built-in procedure for the structure types it supports, with its assumptions and limitations.
Conclusion
Applying wind in STAAD.Pro is mostly about discipline: traceable pressures, careful conversion to loads, clear direction conventions and reaction checks that prove the load went in as intended.
Need wind loads applied and checked correctly?
Solyug Energy's STAAD Pro wind analysis for solar structures covers wind calculation, application and member and foundation checks. Our structural consultancy team can also review an existing model, and you can contact us with your project details.